Maytag Dryer Error Code L2 — Low Voltage
What this means
L2 means the dryer is getting 120V instead of the required 240V. The drum tumbles but the dryer doesn't heat. One side of the double-pole circuit breaker has likely tripped.
Step-by-step fix
2 stepsReset the circuit breaker
Flip the double-pole dryer breaker fully OFF then ON. Both sides must engage.
A double-pole breaker can trip on just one side — it may look on but only half is working.
Test for heat
Run a timed cycle. Feel for heat after 5 minutes. If no heat, the voltage issue persists.
If the breaker keeps tripping, don't keep resetting — call an electrician.
When to call a professional
Repeated tripping means a wiring issue. Call an electrician.
Related error codes
Information compiled from manufacturer service manuals, official troubleshooting documentation, and appliance repair industry resources. This guide is for informational purposes only — always consult a qualified technician for complex repairs.
Learn more about our sourcesParts you may need
No replacement parts typically needed for this fix.
Links may earn us a commission at no extra cost to you. We only recommend parts relevant to this repair.