LG Oven Error Code CFA — Over Current Detected

Professional 45–60 minutes Tools: Multimeter, Screwdriver set

What this means

Error CFA indicates the control board has detected an over-current condition, meaning more electrical current is flowing through the circuits than expected. This can be caused by a shorted heating element, a wiring short, or a control board issue. This is a safety shutdown to prevent electrical damage or fire.

Step-by-step fix

4 steps
1

Turn off the breaker

Disconnect power immediately to prevent further electrical issues.

2

Check heating elements

Test the bake and broil elements for continuity and resistance. A shorted element can cause over-current.

Also test each element to ground — no continuity should exist between the element terminals and the oven frame.

3

Inspect wiring

Look for burned, melted, or shorted wiring inside the oven.

4

Professional diagnosis

If elements and visible wiring check out, the control board may have an internal failure requiring professional diagnosis.

When to call a professional

Over-current conditions involve electrical safety. Professional diagnosis is strongly recommended.

Information compiled from manufacturer service manuals, official troubleshooting documentation, and appliance repair industry resources. This guide is for informational purposes only — always consult a qualified technician for complex repairs.

Learn more about our sources

Parts you may need

Bake Element

Part #MEE62385001 · $30–$60

If element is shorted

Find Part

Control Board

Part #Model-specific · $150–$350

If board has internal failure

Find Part