F24

Kenmore Dryer Error Code F24 — Inlet Thermistor Failure (Shorted)

Advanced 30–45 minutes Tools: Multimeter, Screwdriver set

What this means

Error F24 indicates the inlet thermistor that monitors incoming air temperature has a short circuit. This sensor normally reads approximately 50,000 ohms at room temperature. A shorted sensor reads near zero ohms, giving the control board false temperature readings.

Step-by-step fix

4 steps
1

Locate the inlet thermistor

The inlet thermistor is typically near the air intake area of the dryer.

2

Test with multimeter

Disconnect and test resistance. It should read approximately 50,000 ohms at room temperature. A near-zero reading confirms a short.

3

Check for pinched wiring

A pinched or stripped wire can cause a short circuit that mimics a sensor fault.

4

Replace the thermistor

If the sensor is shorted, replace it.

When to call a professional

If wiring is damaged inside the dryer cabinet, professional repair may be needed.

Information compiled from manufacturer service manuals, official troubleshooting documentation, and appliance repair industry resources. This guide is for informational purposes only — always consult a qualified technician for complex repairs.

Learn more about our sources

Parts you may need

Inlet Thermistor

Part #W10820048 · $10–$25

If sensor is shorted

Find Part

Links may earn us a commission at no extra cost to you. We only recommend parts relevant to this repair.

Quick Info

BrandKenmore
ApplianceDryer
Error CodeF24
DifficultyAdvanced
Est. Time30–45 minutes