Kenmore Dryer Error Code F22 — Outlet Thermistor Failure

Advanced 30–45 minutes Tools: Multimeter, Screwdriver set

What this means

Error F22 indicates the outlet thermistor (temperature sensor) that monitors the exhaust air temperature has failed. This sensor typically reads about 10,000 ohms at room temperature. An open circuit means the sensor wire is broken or the sensor element has failed.

Step-by-step fix

4 steps
1

Locate the outlet thermistor

The outlet thermistor is usually mounted on or near the exhaust duct inside the dryer.

2

Test with multimeter

Disconnect the sensor and test resistance. It should read approximately 10,000 ohms at room temperature.

An open (infinite) reading confirms failure.

3

Check wiring

Inspect the wiring from the sensor to the control board for damage.

4

Replace the thermistor

If it reads open, replace the outlet thermistor.

When to call a professional

Thermistor replacement is a moderate DIY task. Call a pro if you are not comfortable with multimeter testing.

Information compiled from manufacturer service manuals, official troubleshooting documentation, and appliance repair industry resources. This guide is for informational purposes only — always consult a qualified technician for complex repairs.

Learn more about our sources

Parts you may need

Outlet Thermistor

Part #W10820048 · $10–$25

If sensor is defective

Find Part

Links may earn us a commission at no extra cost to you. We only recommend parts relevant to this repair.

Quick Info

BrandKenmore
ApplianceDryer
Error CodeF22
DifficultyAdvanced
Est. Time30–45 minutes